Inspection of the existing building by taking concrete cores for the assessment of compressive strength and carbonation, impact measurement tests, determination of chloride content of concrete per depth (internal-external), ultrasonic speed determination, magnetic reinforcement detection, half-cell potential difference measurements in steel, taking steel samples to determine tensile strength of reinforcement-yield-elongation limit, determination of reinforcement corrosion products.