Hotel Myrtoon, Spetses

Image 3019

Inspection of the existing building by taking concrete cores for the assessment of compressive strength and carbonation, impact measurement tests, determination of chloride content of concrete per depth (internal-external), ultrasonic speed determination, magnetic reinforcement detection, half-cell potential difference measurements in steel, taking steel samples to determine tensile strength of reinforcement-yield-elongation limit, determination of reinforcement corrosion products.